Issue
Pumps used by the military are refurbished after a period of service. The military require pumps to be operationally ready when pulled from stores.
Solution
Following their refurbishment they are preserved from corrosion using a mix of Mil Spec and commercial off-the shelf (COTS) materials.
In this case the pump has been protected aganist corrosion using the following components:
- vapor capsule inside the electrical control box
- plastabs inside junction boxes
- high performance desiccant inside the package to absorb water
- barrier film to Mil Spec on the outside
Benefits
- pump is preserved in the same state as it is after refurbishment
- operational ready
- no rework required